Labor Law 274 — Legislation
No judge's part rules on file currently cite this section by name.
Text
Legislation
Search OpenLegislation Statutes
Search Term
Search icon
Search
previous
SECTION 273
Fire-escapes erected after October first, nineteen hundred and thirteen, on buildings theretofore erected
up
TITLE 3
Fire Hazard
next
SECTION 275
Special laws and local ordinances
Viewing most recent revision (from 2014-09-22)
View historical revision as of:
-- Choose a Date -- 2014-09-22
Share
Facebook
Email
SECTION 274
Fire-escapes erected before October first, nineteen hundred and thirteen
Labor (LAB) CHAPTER 31, ARTICLE 11, TITLE 3
§ 274. Fire-escapes erected before October first, nineteen hundred and
thirteen. All outside fire-escapes erected before October first,
nineteen hundred and thirteen, and serving as required exits under the
provisions of section two hundred and seventy-one shall conform to the
following requirements:
1. There shall be balconies on each floor of the building connected
with stairways placed at an angle of not more than sixty degrees.
2. A stairway shall lead from the top floor balcony to the roof,
except when the fire-escapes are erected on the front of the building.
3. A stairway not less than twenty-two inches wide shall lead from the
lowest balcony to a safe landing place beneath, which stairway shall
remain down permanently or swing up and down by counterbalancing
weights.
4. A safe and unobstructed exit shall be provided to the street from
the foot of such fire-escapes as required in subdivision nine of section
two hundred and seventy-three.
5. Steps shall connect the sill of every opening leading to the
fire-escapes with the floor wherever such sill is more than three feet
above the floor level.
6. All openings leading to the fire-escapes shall be provided with
fireproof windows or fire doors.
7. All windows opening upon the course of the fire-escape shall be
fireproof windows.